Weather stations
Air temperature control on the farm is essential for anti-frost controls.
Basic station:
nMETOS 80
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
Advanced station:
mMETOS Frost
It includes the following sensors:
Wet Bulb/Dry Temperature.
The wet bulb temperature more accurately represents the temperature of the leaves of the crop. It will drop in temperature earlier than the dry bulb temperature, allowing early notification of frost conditions.
Knows the optimal spraying and fertigation timing
Basic station:
nMETOS 80
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
Estación avanzada:
μMETOS Pulverización
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Wind Speed & Direction – Drift
Possibility of using 30, 40, 60, 80, 90 or 120 cm probes.
Possibility of incorporating a flowmeter or rain gauge.
Possibility of incorporating other climatic sensors
Monitor your farm’s own climatic conditions and be alerted to anticipate possible diseases.
Basic station:
nMETOS 180
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Leaf Wetness – Disease Models (calculated)
- Rain gauge
Intermediate station:
nMETOS 200
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Leaf Wetting – Disease Models
- Rain Gauge
- Leaf Wetness Sensor
Advanced station:
mMETOS 200
It includes the following sensors:
Temperature & Relative Humidity of the air
Delta T – Optimum Spray Timing
Dew Point – Frost Protection
DPV – Optimum Fertigation Timing
Leaf Wetting – Disease Models
Rain Gauge
Leaf wetness sensor
Possibility to incorporate other climatic and soil sensors
Basic station:
μMETOS 280 ET0
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Rain Gauge
- Solar Radiation
- Wind speed and diection
- EVAPOTRANSPIRATION – Penman-Monteith Calculation
Possibility to add soil sensors
Advanced station:
iMETOS 3.3 280 ET0
It includes the following sensors:
Temperature & Relative Humidity of the air
Delta T – Optimum Spray Timing
Dew Point – Frost Protection
DPV – Optimum Fertigation Timing
Rain Gauge
Solar Radiation
Wind speed and diection
EVAPOTRANSPIRATION – Penman-Monteith Calculation
Possibility to add soil sensors and more specific sensors
Basic station:
μMETOS 300 ET0 + Diseases
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Rain Gauge
- Leaf Wetness
- Solar Radiation
- Wind speed and direction
- Evapotranspiration
Access to Disease Models (annual fee)
Possibility to add soil sensors
Advanced station:
iMETOS 3.3 300 ET0 + Diseases
It includes the following sensors:
Temperature & Relative Humidity of the air
- Delta T – Optimum Spray Timing
- Dew Point – Frost Protection
- DPV – Optimum Fertigation Timing
- Rain Gauge
- Leaf Wetness
- Solar Radiation
- Wind speed and direction
- Evapotranspiration
Access to Disease Models (annual fee)
Possibility to add soil sensors